The final design walks and stops safely in simulation, but it's about 3.6 metric tons over the weight limit established in the initial requirements. I paused the project on October 30.
I think the interesting part is how it got there, because the first version weighed 15,883 kg, just 117 kg under the limit, and walked 10 steps in simulation. It took three independent engineering reviews to establish that the design wouldn't work.
What I was trying to build
Robot30 is a design study for a 9.144 m (30 ft) walking humanoid robot, intended to operate on a paved demonstration pad.
I wanted it to be genuinely working, rather than just something that looked plausible in a render.
The design has 34 actuated joints, including 24 hydraulic linear actuators, 2 hydraulic rotary actuators, and 10 electric actuators. The hydraulic power unit sits in the torso, driven by a Cummins QSB6.7 diesel engine rated at 224 kW and weighing 658 kg.
I used real component specifications throughout the design, including Rexroth A4VSO 355 pumps, Moog servo valves, and HYDAC accumulators.
There's no cockpit. The robot is controlled from a ground console, with a separate spotter holding a wireless emergency stop.
The first milestone established 33 requirements, including three main performance targets:
- Maximum mass of 16,000 kg.
- At least 4 hours of runtime.
- Walking speed of 0.20 m/s.
My goal was for the robot to genuinely work. One of the rules I gave Claude Code was that tests needed to check real numbers, and when something failed, it had to change the design rather than the threshold.
All of the engineering was done through Claude Code sessions I directed, with a separate AI reviewer grading each phase and independently recalculating the numbers.
This is important to clarify: nothing has been physically built, quoted, or ordered. The project consists of engineering documents, component selections, calculations, and a MuJoCo simulation. All of the prices are budget estimates.
The first version
The initial design was completed across eight milestones on October 26–27.
Those covered 33 requirements, the MuJoCo model, hydraulics, finite-element structural analysis, electrical systems and safety, manufacturing, the carbon-fibre exterior, and a validation matrix.
By milestone eight, the robot weighed 15,883 kg, which was 117 kg below the limit.
In simulation, it walked 10 steps covering 9.01 m in 53.5 seconds. It also completed 5-degree uphill, downhill, and cross-slope tests.
The bill of materials came to €954,894, or €1,098,129 with a 15% contingency. The heaviest single assembly lift was the 3,835 kg upper-body module, requiring a 5-ton crane.
At this point, the design looked pretty good on paper. It was within the weight limit, the simulation showed it walking, and the component selections were tied to real hardware.
Then I had three independent reviewers evaluate it.
All three concluded it wouldn't work.
The reviews
The structural and dynamics reviewer gave the design a pretty straightforward verdict:
"WOULD NOT WORK"
The walking controller required more torque-loop bandwidth than the hydraulic system could deliver. The emergency fall-arrest kneel required more knee flexion than the joint physically allowed, and the governing structural welds failed fatigue requirements.
The hydraulics reviewer calculated that the leg control loops could achieve only 0.26–0.66 Hz, against a requirement of 3 Hz.
It then ran the simulation using those bandwidths.
"I ran the sim with those bandwidths and the robot falls at t = 4.79 s"
The safety reviewer found a different set of problems. Components that weren't actually independent had been counted as redundant safety channels. The emergency-stop fallback could leave 16 tons rocking on the edge of one foot, and there was no hose-burst analysis.
Its assessment was that the walking controller worked, but only in an idealised simulation.
There was also a review of how the robot looked, which I thought was pretty funny.
"A tidy engineering mock-up. It is not a cool giant robot until it has a head, a heroic silhouette, surface detail and human scale in the shot."
That was a fair criticism too.
The main issue, though, was that the initial walking controller only worked in an idealised simulation. When the reviewers accounted for the designed hydraulics' leg-loop bandwidth of 0.26–0.66 Hz against the 3 Hz requirement, the robot fell.
Getting it to walk
I split the next part of the project into separate phases, starting with getting the robot to stand and walk using a more realistic hydraulic model.
The first two review rounds failed.
On the third round, the reviewer passed the design, but with an important qualification.
The original gait was targeting 0.21 m/s. Once the legs were simulated with realistic hydraulic response, that gait fell.
The gait that remained stable across the full tested actuator-error range was only 0.143 m/s.
The reviewer marked it:
"PASS (honest limit)"
I actually liked that result.
The robot was slower than I wanted, but it was much more useful to know that than to have a simulation reporting a walking speed the hardware couldn't achieve.
It also meant the original 0.20 m/s requirement was still unmet.
Making a 16-ton robot stop safely
The next phase was safety, which turned out to be considerably more difficult.
It failed six review rounds before passing on the seventh.
The review had 36 criteria, and the scores across rounds four through seven were 32, 33, 35, and finally 36.
One of the biggest problems was what happened when the emergency stop was pressed while the robot was standing on one foot.
The initial fallback could leave the lifted foot frozen, with the robot remaining on one foot. At 75% single support, the worst settled stability margin was only 0.057 m.
The revised system vents the swing knee, allowing the lifted foot to drop and land instead of leaving the robot balancing on one leg.
At 75% single support, the worst settled stability margin improved from 0.057 m to 0.776 m.
The hydraulic safety system also gained two independent blocking valves on every gravity-loaded cylinder port.
For a simulated hydraulic line burst, the valves close 77 ms after the break, with approximately 3.4 L of oil lost.
Eventually, the reviewer passed all 36 safety criteria.
That doesn't mean the robot is safe to operate around people.
The design cannot achieve PL e, the highest safety performance level. Instead, its operating concept depends on keeping everyone outside the robot's calculated 12.9 m fall reach.
The console and spotters would operate behind a barrier at 15.0 m.
For a machine this size, keeping people away from it is a pretty important part of the design.
The weight problem
This was where the project started becoming much more complicated.
The original robot weighed 15,883 kg, so I only had 117 kg of margin.
When the power unit was recalculated using the reviewer's component requirements, the heat load came out to 171 kW rather than 118 kW.
The 224 kW engine also couldn't sustain the walking power peaks, which reached 388 kW without limiting.
The accumulators dropped 2.65 MPa below the cylinders' required minimum pressure.
One leg circuit alone demanded up to 830 L/min during the 10-step walk, while the pump could supply only 506 L/min. The accumulator had to cover the difference.

A power-unit configuration that passed its checks brought the robot to 16,882 kg, with only 3.4 hours of walking runtime.
So fixing the power system broke the mass and runtime requirements.
Then the structural changes started adding even more weight.
Every time the robot got heavier, the loads on the legs increased. Those larger loads required stronger shins and feet, which made the robot heavier again.
Here's how the mass changed across the fix sessions and the final item-by-item run:
| Stage | Robot mass |
|---|---|
| Initial design | 15,883 kg |
| Fix session | 16,186.9 kg |
| Fix session | 16,218 kg |
| Fix session | 17,042.7 kg |
| Fix session | 17,279.4 kg |
| Fix session | 17,479.6 kg |
| Fix session | 19,080.6 kg |
| Item-by-item method, final | 19,590 kg |

After the fix session that brought the mass to 19,080.6 kg, the reviewer predicted:
"Expect about 19.5-20 t converged unless the slope-up demand becomes a design variable"
That prediction turned out to be pretty close.
I also tried reducing the uphill walking speed to save weight, but the resulting design needed thicker shins and feet, adding another 670 kg.
At this point, it was becoming clear that fixing one problem at a time wasn't necessarily going to produce a design that met all of the original requirements.
Trying two different approaches
On October 30, I ran two engineering approaches side by side on separate copies of the design.
The first approach continued fixing the reviewer's failing items individually.
The second approach performed one global sizing pass across every structural member, attempting to solve the weight and loading problem together.
I then had a blind reviewer compare the results.
The item-by-item approach finished at 19,590 kg and passed 17 of 36 review criteria.
The global sizing approach finished at 21,372.1 kg, passed only 11 of 36 criteria, and had 50 failing tests. Its mass-sizing loop wasn't converging.
The blind reviewer selected the item-by-item approach.
The phase-three review scores had progressed from 12 to 14 to 21 out of 36 during the earlier review rounds, but the final comparison still didn't produce a fully passing design.

The final mass review included this:
"AC-6: 19,589.8 vs 16,000 kg (-3,590) ... No AC lever recovers 3.6 t"
The design was now about 19.6 metric tons, compared with the original 16-ton limit.
And I didn't have a demonstrated way to remove that extra mass while keeping the other requirements intact.
What actually works
The current design walks and stops safely in the tested simulation conditions, and the dedicated safety review passed all 36 criteria.
But it doesn't meet all of the original requirements.
The stable walking speed is 0.143 m/s instead of 0.20 m/s, and the mass is about 19.6 tons instead of 16 tons.
At the earlier fix-2 configuration, the runtime calculation showed 4.9 hours of continuous operation or 8.1 hours across a demonstration day. Those numbers shouldn't be treated as verified runtime for the final 19.6-ton configuration.
There are also several important things that haven't been completed.
The hydraulic schematics, manifolds, wiring diagrams, control software, and CE documentation are still unfinished. Approximately €0.11 million of components remain open for selection.
Wind and recovery from a push while stepping haven't been simulated.
One of the more interesting limitations came from the obstacle tests.
Putting a 10 cm stone under a footstep caused the robot to fall in all four tested cases.
So the operating rule became a prepared paved pad with no obstacles larger than 2 cm.
It's a 30-foot robot that can walk in simulation, but only under fairly controlled conditions.
What I think of the results
I think the most interesting part of this project is that the initial design looked like it worked.
It was under the weight limit, it walked in MuJoCo, and it had a detailed bill of materials using actual industrial components.
If I'd stopped at milestone eight, I could've described it as a completed 30-foot walking robot design.
But the independent reviews showed that the hydraulic control system couldn't actually reproduce the simulated gait, the emergency-stop behavior wasn't safe, and the structural assumptions didn't hold up.
Then fixing those problems caused the mass to increase by several tons.
I think this is a useful example of both what AI engineering tools are becoming capable of and where the difficulty still is.
Claude Code was able to produce a fairly detailed mechanical design, work through hydraulic calculations, build a simulation, and revise the system across multiple rounds of engineering feedback in a few days.
But generating a design that satisfies a collection of tests isn't the same as producing a physically viable machine.
The tests themselves have to represent the actual engineering constraints, and the reviewers have to be willing to fail the design.
That's why I made the rule about never changing a threshold just because a test failed.
Otherwise, I could've increased the mass limit, reduced the walking speed requirement to 0.143 m/s, and called the project successful.
That wouldn't answer the question I was trying to investigate.
I wanted to know whether the robot could be designed to meet the original requirements, and so far the answer is no.
There's also a difference between the safety review passing and the machine being ready to build. The current simulation doesn't cover every real-world failure mode, and there are still substantial engineering deliverables missing.
I paused Robot30 on October 30.
The remaining decision is whether I'm willing to accept the overweight robot.
I haven't made that decision yet.
I think it's more interesting to have a 30-foot robot design that fails its requirements honestly than one that passes because I kept changing the requirements until it did.